Qualification system for grounding transformers
Netze BW GmbH, Stuttgart
- Frist (abgelaufen)
- keine Frist angegeben
- Geschätzter Wert
- nicht angegeben
- Verfahren
- Lieferung
- Ort der Leistung
- Karlsruhe (Stadtkreis) · Baden-Württemberg
- Veröffentlicht
- Laufzeit
- 28.04.2026 bis 31.12.2032
- Für KMU geeignet
- keine Angabe des Auftraggebers
- Branche
- Elektrotechnik
- CPV
- 31171000 Transformatoren mit Flüssigkeitsisolation
Beschreibung
The present qualification system serves as the prequalification for the supply of grounding transformers for the medium‑voltage network (10-30 kV). It ensures that all potential suppliers comply with the technical requirements of our specification as well as the commercial and procedural criteria necessary for approved supplier status.
4 Lose
- Los 1Grounding transformer with 10kV and 350A
Lot 1 - NEB 10 kV / 350 A This lot covers a Grounding Transformer (NEB) with the following main characteristics: Vector group ZNyn5(d), cooling type ONAN, designed for short-term operation of 2 hours. The rated high-voltage level is 10.4 kV with a rated current of 350 A. The rated low-voltage level is 0.4 kV with a rated power of 400 kVA. The specified zero-sequence impedance is 3.5 Ω per phase. …
ohne Wert - Los 2Grounding transformer with 20kV and 800A
Lot 2 - NEB 20 kV / 800 A This lot covers a Grounding Transformer (NEB) with the following main characteristics: Vector group ZNyn5(d), cooling type ONAN, designed for short-term operation of 2 hours. The rated high-voltage level is 21 kV with a rated current of 800 A. The rated low-voltage level is 0.4 kV with a rated power of 400 kVA. The specified zero-sequence impedance is 3.5 Ω per phase. …
ohne Wert - Los 3Grounding transformer with 20kV and 433A
Lot 3 - NEB 20 kV / 433 A This lot covers a Grounding Transformer (NEB) with the following main characteristics: Vector group ZNyn5(d), cooling type ONAN, designed for short-term operation of 2 hours. The rated high-voltage level is 21 kV with a rated current of 433 A. The rated low-voltage level is 0.4 kV with a rated power of 400 kVA. The specified zero-sequence impedance is 3.5 Ω per phase. …
ohne Wert - Los 4Grounding transformer with 30kV and 280A
Lot 4 - NPB 30 kV / 280 A This lot covers a Grounding Transformer (NPB) with the following main characteristics: Vector group ZN, cooling type ONAN, designed for short-term operation of 2 hours. The rated high-voltage level is 31,5 kV with a rated current of 280 A. The specified zero-sequence impedance is 10.5 Ω per phase. All applicable requirements shall comply with DIN IEC 60076.
ohne Wert
Ähnliche offene Verfahren
Elektrotechnik in Deutschland, nach Frist sortiert. Alle anzeigen
- heute, in 3 StundenKG440 Elektroinstallationen | Pfrondorfer Straße 36Universitätsstadt Tübingen - Zentrale Vergabestelle · Öffentliche Ausschreibung · TübingenTübingennicht angegeben
- heute, in 3 StundenPolizeipräsidium, Gesamtsanierung Elektroarbeiten (Gesamtsanierung Altbau)Vermögen und Bau Baden-Württemberg, Amt Heilbronn · Offenes Verfahren · Heilbronn · 4.092.376 €Heilbronn4.092.376 €
- morgenInstandsetzung des Glasfasernetzes der Bob- und Rodelbahn WinterbergHochsauerlandkreis · Öffentliche Ausschreibung · WinterbergWinterbergnicht angegeben
- morgenZoo Restaurant MSRStadt Frankfurt am Main, Amt für Bau und Immobilien · Offenes Verfahren · Frankfurt am MainFrankfurt am Mainnicht angegeben
- morgenBImA, Bundespolizei Blumberg, Strangsanierung Gebäude 7 und 8, Erweiterung Sicherheitsbeleuchtungsanlage an den Fluchttürmen am Gebäude G7 und G8Brandenburgischer Landesbetrieb für Liegenschaften und Bauen (BLB) - Zentrale Vergabestelle · Offenes Verfahren · BlumbergBlumbergnicht angegeben
- morgenKAW Northeim - Neubau Betriebshof - Lieferung und Montage einer AufzugsanlageLandkreis Northeim · Offenes Verfahren · MoringenMoringennicht angegeben